Site Search:  

Low Cost and small CO2 Sensor Modules

Electro Optical Components introduces a series of low cost CO2 NDIR sensor modules for gas detection applications including indoor air monitoring, agriculture etc. The EOC-IR300 (link) is more accurate and faster. The EOC-PCL0A2K (link) is the smallest CO2 detector available and is lower in cost.

The EOC-IR300 and the EOC-PCL0A2K are NDIR CO2 gas modules that have a precision light chamber, state of the art electronics and intelligent software. With the help of single light source, dual channel detector, and microprocessor, both modules can accurately measure the gas concentration.  Both systems are great for applications like indoor air monitoring, ventilating system, cars etc. The EOC-PCL0A2K (link) is really small (nothing is smaller).

EOC-IR300 Low Cost CO2 Module

In the EOC-IR300 Module, (link) temperature compensation is included as well as firmware to null out any nonlinearity. It has all the advantages of NDIR gas detection including good selectivity, high sensitivity, long life and independence from O2 interference. You can accurately measure CO2 using flow through or diffusion.
EOC-IR300 Module Description Min Typical Max Unit
Detection range 0 2000 50000 ppm
Detection accuracy - ±50ppm±3% FS - ppm
T90 diffusing - 60 90 Sec
pumping - 10 20 Sec
Repeatability Zero - <±80 - ppm
50% FS - <±8% FS -  
Lifetime 3 5 10 Year



EOC-PCL0A2K Small and Lower Cost CO2 Module

The EOC-PCL0A2K is really small (10 x 10 x 31mm!!!) and low cost but it still has all the advantages of other NDIR products, such as good selectivity, high sensitivity, long life and is not interfered with when O2 is present. With the help of single light source, single channel detector, and microprocessor, EOC-PCL0A2K can perform the gas concentration signal in different ways. In this product, temperature compensation has been realized as well as the revision of the nonlinear relationship. The EOC-PCL0A2K has the function of self calibration in every 24 hours.

 


10 x 10 x 31 mm
EOC-PCL0A2K  
Detection accuracy ±50ppm±5% reading
Detection Range
Response time T90
0-2000 ppm
<3 minutes
Warm-up time Set to work <60 seconds
  Precision reached <15 minutes